SOUNDPROOFED IT RACK FOR DATA CENTER

Soundproofed rack for data center with thermostatic cooling. Rack-mount cabinets available on 12U | 24U | 42U

  • Up to 31 dB noise reduction 
  • Innovative air-flow design for effective thermal dissipation of 12 kW 
  • Up to 6 cable entry points can be used 
  • All doors and both side panels are easily removed for installation and maintenance access 
  • Front and rear doors each have one swing handle with lock 
  • Easy to deploy – just plug and go 
  • 4 casters wheels including 2 with brakes 
  • Loading capacity : 1500 kg* | 3306 lbs 
  • Fire rating Euroclass (D4225, EU5034) 
  • Light grey with orange trim as standard. Black with orange trim also available
    *Static position

SOUNDPROOFED RACK MOST ADAPTED FOR : DATA CENTER | LOUD COMPUTER EQUIPMENT | NETWORK EQUIPMENT

Previous
Next

Physical rack capacity : 12 | 24 or 42 x EI 1 3/4″ / 44.5mm rack spaces ; 4 post rack, fully EIA-compliant, with adjustable front & rear mounting profiles 
Maximum distance between mounting profiles : 794 mm | 31.25 inches 
Internal cabinet depth : 917 mm | 36.10 inches 

IF YOU NEED A SPECIFIC SIZE, WE HAVE A SOLUTION !
FEEL FREE TO CONTACT US !

Soundproofed rack for data center grey

FEATURES & BENEFITS

EC FAN TECHNOLOGY

Energy saving and hot air swappable 

lcd_13619
LCD DISPLAY

Displaying alarm state and major monitoring points 

SWING HANDLE & TWO POINT LOCKING

Providing high security-electronic upgrade available 

49-494295_cable-icons-free-and-power-cable-icon
FOAM CABLE ENTRY SYSTEM

Speedy installation without compromise to performance 

tyre_86126
HEAVY DUTY CASTORS (STANDARD)

Plinth corners, leveling feet (optional upgrade)
For safe and rapid deployment

water-drop_37963
IP 54 UPGRADE OPTION

IP 44 as standard for protection from dust ingress 

2432218
DOOR DUST FILTERS (OPTIONAL UPGRADE)

Door dust filters (optional upgrade) Providing a dust free operational environment

REDUCE NOISE TO A TOLERABLE LEVEL : -15 db(A)

WHY USE A MS NOISE SOUNDPROOF IT RACK ?

MANAGEMENT SYSTEM EMS

A standard feature of the MSEDGE 3 is the inclusion of the EDGE management system EMS controlling the 2x EC Fans the environmental of the cabinet with up to 4 temperature and humidity reporting and alarming if over threshold is reached 

Additional contact sensors to notify of door access. Displayed on an easy to view Webui with the SNMP trap send, V1, 2 and 3 available to end out the data and alarms 

Whilst it is the EMS which takes care of the energy efficient cooling, it is also the EMS which brings together the whole solution. Alarms and alerts in real time will notify you of any issues with your cabinet. The LCD screen on the cabinet will also show an alarm status, touch will provide sensor data, fan status and contact sensor triggers. 

CABLING
Previous
Next

Cable entry points – 6 locations. 
The MSEDGE-3 is supplied with 6 gland plates, 3 in the top and 3 in the base. Each of theses plates can be removed and replaced with a foam block fit for cable entry purposes. One cable entry foam block kit is supplied as standard and you can purchase up to 5 additional kits. 

The diagram below shows the positioning of the top and bottom gland plates. Cable entry point dimensions are 330×75 mm and each activated cable entry point accommodates up to 120 CAT5/6 cables or equivalent